Schneider Electric Residual Current Circuit Breaker Acti 9 xID 4 Pole 25A 30mA AC-Type
Plan Details
Free installation service

Schneider Electric Residual Current Circuit Breaker Acti 9 xID 4 Pole 25A 30mA AC-Type

Features
  • 12 Months cover from date of purchase for New Smart Phones
  • Repair of device for Accidental and/or Liquid damage.
  • Max 2 repair requests, cumulatively capped upto the device invoice value.
  • Like to Like replacement
  • Free Pick-up & Drop
  • 14 Working Days TAT
Description

Ever accidentally spilt coffee, tea or water on your phone? Did your phone ever get drenched in the rain? All of these can damage parts within your phone and make it unusable or non-responsive just when you most need it. Smartphones are fragile and prone to physical damage. So we recommend you buy this accidental damage and liquid protection cover. Fixing a liquid damaged Smartphone is expensive and time consuming if it isn't covered under the manufacturer warranty or extended warranty. Buying this Extended Warranty for your smartphone will protect your phone for 12 months.

Specifications
Validity 1 Year
Brand Reliance Retails
Warranty 1 Year on handset. 6 months on accessories
Return Policy

Items are eligible for return within 7 Days of Delivery*. All accessories, product & packaging need to beEver accidentally spilt coffee, tea or water on your phone? Did your phone ever get drenched in the rain? All of these can damage parts within your phone and make it unusable or non-responsive just when you most need it. Smartphones are fragile and prone to physical damage. So we recommend you buy this accidental damage and liquid protection cover. Fixing a liquid damaged Smartphone is expensive and time consuming if it isn't covered under the manufacturer warranty or extended warranty. Buying this Extended Warranty for your smartphone will protect your phone for 12 months.

Price Details

Samsung 138 cm smart television with Pureview QLED

1 Year resQ Care Plan. Accidental and liquid damage Protection for LCD

Amount Payable:

Features & Details
  • Schneider Electric A9N16251 Acti 9 RCCB xID 4P 25A 30mA AC-type
Description
Acti 9 xID residual circuit breaker 25 A 4P 30mA class AC instantaneous. Label Acti 9 xID and ID 125 RCCBs range of product Acti 9 [In] rated current 25 A network type AC earth leakage sensitivity 30 mA earth leakage protection time delay instantaneous earth leakage protection class type AC rated breaking and making capacity N/A range Acti 9 suitability for isolation yes product name Acti 9 xID product or component type residual current circuit breaker (RCCB) device short name xID poles description 4P neutral position left Range Presentation Nominal current up to 125A 30mA sensitivity additional protection against direct contact (in accordance with IEC 364) 100, 300, 500 mA sensitivities additional protection against fire and indirect contact (in accordance with IEC 364) Class AC for normal installation Class Si (New) for electrically disturbed networks (with harmonics, pulsating DC components etc.) & for harsh environments (presence of corrosive atmosphere, chemical gases, humid location etc) 4P RCCB is also suitable for 3phase 3 wire installation Conforms to IS 12640 and IEC/EN 61008 ISI and CE marked Suitable for isolation in accordance with industrial standards IEC 60947 Intermediate auxiliary required for add on protection and indication auxiliaries ID 125 RCCBs are suitable for indication OFsp auxiliary only Suitable for additional Protection and Indication auxiliaries ON/OFF, Trip, Shunt trip, Undervoltage trip, Overvoltage trip, Communication Auxiliary Range Benefits Easy monitoring Earth fault indication on front face Immunity against nuisance tripping New SI RCDs offers enhanced immunity to electrical disturbances and polluted & corrosive environments Ensures no accidental contact with live part – Finger proof IP 20 terminals Avoids false insertion of cables and loose termination with Pull up terminals Environmentally friendly with 100% recyclable & recoverable materials. Range Application Presentation Protection in all industrial and commercial buildings against Electrocution (in accordance with installation standard IEC 60364 and national standards) The risk of fire due to current leakage into building electrical installations.
Product Information
General Information
Brand Schneider Electric
Manufacturer Schneider Electric
Manufacturer Address

Schneider Electric
DLF Building, Tower C, N-10, DLF Cyber City, DLF Phase 2, Sector 24, Gurugram, Haryana 122002

Sold By ELECTRICAL CONTROL SYSTEMS PRIVATE LIMITED
JioMart Customer Care Phone 1800 890 1222
Marketed By ELECTRICAL CONTROL SYSTEMS PRIVATE LIMITED
Included Components Pack of 1 Residual Current Circuit Breaker
Country of Origin India
Product Details
Color White
Material Plastic
Usage Details
Hazardous Material No
Net Quantity 1
Product Specifications
Product Type Circuit Breaker & Panels
Item Dimensions
Height 10 cm
Length 10 cm
Width 10 cm
Net Weight 300 g
Article ID: RVV1DZUZBW
Sellers
Schneider Electric Residual Current Circuit Breaker Acti 9 xID 4 Pole 25A 30mA AC-Type
Schneider Electric Residual Current Circuit Breaker Acti 9 xID 4 Pole 25A 30mA AC-Type
more sellers
EMI Details
Debit Card EMI
Loading..